- Output power
- 360 W (0.6 kVA)
- Topology
- Line-interactive with AVR
- Output waveform
- pseudo-sine wave
- Input voltage range
- 162–290 V
- Rated input/output voltage
- 230 V
- Frequency
- 50 Hz
- Transfer time
- 2 ms
- Rechargeable battery
- 12 V, 7 Ah (1 pc.); cold start supported; charging up to 90% ≈ 6 h
- Noise level
- 40 dB
- Output voltage regulation
- ±10%
- AC outlets
- 2 (Type F)
- Form factor and colour
- tower, black
- Display
- LCD with LED indicators
- Operating conditions
- 0–40 °C, 0–95% relative humidity
- Dimensions (W×D×H)
- 101 × 298 × 142 mm
- Weight
- 4.35 kg
- Battery capacity (VA)
- 600 VA
- Output power (W)
- 360 W
- Charging time (hours)
- 8h
- Number of outlets (Battery Backup)
- 2
- Socket type
- Schuko
- Battery capacity
- 7 Ah
- Battery voltage
- 12 V
- Battery charge time (90%)
- 6 h
- Number of supported batteries
- 1
- Cold start
- Yes
- Nominal input voltage
- 230 V
- Depth
- 150 mm
- Display type
- LCD
- Form factor
- Tower
- LED indicators
- Yes
- Product colour
- Black
- Warnings
- Use the device in well-ventilated rooms to avoid overheating.
- Operating relative humidity (H-H)
- 0 - 95%
- Operating temperature (T-T)
- 0 - 40 °C
- Filters / protection
- Overcharge
- Overvoltage protection
- Yes
- Automatic restart
- Yes
- Input operating voltage (max.)
- 290 V
- Input operating voltage (min)
- 162 V
- Input frequency
- 50 Hz
- Power protection features
- Battery discharge
- Surge protection features
- Modem
- Transfer time (from line mode to battery mode)
- 2 ms
- Beep modes
- Alarm signal when running on battery, fault, low battery alarm, overload alarm
- Audible alarm(s)
- Yes
- UPS topology
- Line-Interactive
- Waveform
- Pseudo sine wave
- I/O ports
- None
- Input power ports
- Type F Schuko
- Number of input phases
- 1 (230V)
- Power output ports
- 2 x type C/F (Schuko)
- Dimensions
- Height 142 x width 101 x depth 298 mm
- Output voltage waveform
- Modified sine wave
- Number of AC outlets
- 2 AC outlets
- Power plug
- Type F
- USB port
- No
- Height
- 142 mm
- Depth
- 298 mm
- Width
- 101 mm
- UPS architecture
- Line-interactive
- Charging time
- 8 h
- Runtime (max.)
- 6 ms
- Environmental requirements
- Humidity: 0–95% relative humidity within a temperature range of 0 °C to +40 °C (non-condensing) Noise level: less than 40 dB
- Chassis type
- Desktop
- Apparent power
- 600 VA