ETEKOSSHOP IT services (in a new tab)
English

About this product

The TP-LINK TL-SX3008F is an Omada series L2+ managed switch designed for the aggregation layer, offering 8× 10 Gbps SFP+ slots for high-bandwidth connections. The device has 160 Gbps switching capacity and a packet forwarding rate of 119.04 Mpps, enabling an efficient 10G network infrastructure. The switch supports static routing, VLAN, ACL, QoS and IGMP Snooping, as well as ERPS fast ring protection.

Management is possible via a web interface, CLI, SNMP and RMON, as well as centrally with an Omada controller or app. The device features a fanless design for quiet operation, a durable metal housing and rack mounting. Maximum power consumption is 15.46 W, and it operates in a 100-240 V AC voltage range.

Switches / TP-LINK

TP-LINK Omada switch SX3008FSwitch

291,32 €

incl. VAT

✓ In stock

Price and availability checked

  • Courier to your address from 15,73 €
  • Delivery within 5-7 working days after payment
Other products in this category
Manufacturer
TP-LINK
Model code
SX3008F
EAN
6935364006457

Technical specifications

Hardware specifications

Interface
• 8× 10GE SFP+ Slots • 1× RJ45 Console Port • 1× Micro-USB Console Port
Number of fans
Fanless
Physical security lock
√
Power
100-240 V AC~50/60 Hz
Dimensions (W x D x A)
17.3×7.1×1.7 in (440×180×44 mm)
Mounting
Rack-mountable
Maximum power consumption
15.46 W (220 V / 50 Hz)
Maximum heat dissipation
52.75 BTU/hr (220 V / 50 Hz)

Performance

Switching capacity
160 Gbps
Data packet forwarding rate
119.04 Mpps
Address table size
32 K
Packet buffer memory
16 Mbit
Large data frames (Jumbo Frame)
9 KB

Software specifications

Data flow priorities (QoS)
• 8 priority queues • 802.1p CoS/DSCP priority • Queue scheduling: SP (Strict Priority), WRR (Weighted Round Robin), SP+WRR • Bandwidth Control: Port/Flow-based Rating Limiting • Smoother Performance • Action for Flows: QoS remark (802.1P Remark, DSCP Remark)
L2 and L2+ features
• 128 IP Interfaces: Support IPv4/IPv6 Interface • Static Routing: 48 IPv4/IPv6 Static Routes • Static ARP: 128 static entries • 512 ARP Entries • Proxy ARP • Gratuitous ARP • DHCP Server • DHCP Relay: DHCP Interface Relay, DHCP VLAN Relay • DHCP L2 Relay • Link Aggregation • Spanning Tree Protocol • Loopback Detection • 802.3x Flow Control • Mirroring
L2 group addressing
• Supports 1000 (IPv4, IPv6) IGMP groups • IGMP Snooping • IGMP Authentication • Multicast VLAN Registration (MVR) • MLD Snooping • Multicast Filtering: 256 profiles and 16 entries per profile
Additional options
• Automatic Device Discovery † • Batch Configuration † • Batch Firmware Upgrading † • Intelligent Network Monitoring † • Abnormal Event Warnings † • Unified Configuration † • Reboot Schedule † ISP Features *: • L2PT (Layer 2 Protocol Tunneling) • Device Link Detect Protocol (DLDP) • PPPoE ID Insertion • ERPS • 802.3ah Ethernet Link OAM • DDM • sFlow
Virtual network segments (VLAN)
• VLAN Group (802.1q VLAN): Max 4K VLAN Groups • 802.1Q Tagged VLAN • MAC VLAN: 30 Entries • Protocol VLAN: Protocol Template 16, Protocol VLAN 12 • Private VLAN • GVRP • VLAN VPN (QinQ): Port-Based QinQ, Selective QinQ • Voice VLAN
Access control list (ACL)
• Time-based ACL • MAC ACL: Source MAC, Destination MAC, VLAN ID, User Priority, Ether Type • IP ACL: Source IP, Destination IP, Fragment, IP Protocol, TCP Flag, TCP/UDP Port, DSCP/IP TOS • Combined ACL • Packet Content ACL • IPv6 ACL • Policy: Mirroring, Redirect, Rate Limit, QoS Remark • ACL applies to Port/VLAN
Security
• IP-MAC-Port Binding - 512 Entries - DHCP Snooping - ARP Inspection - IPv4 Source Guard • IPv6-MAC-Port Binding - 512 Entries - DHCPv6 Snooping - ND Detection - ND Snooping - IPv6 Source Guard • DoS Defend • Static/Dynamic Port Security: Up to 64 MAC addresses per port • Broadcast/Multicast/Unicast Storm Control: kbps/ratio control mode • 802.1X - Port base authentication - MAC-based authentication - VLAN Assignment - MAB - Guest VLAN - Radius authentication and accountability support • AAA (including TACACS+) • Port Isolation • Secure web management through HTTPS with SSLv3/TLS 1.2 • Secure Command Line Interface (CLI) management with SSHv1/SSHv2 • IP/Port/MAC-based access control
IPv6
• IPv6 Dual IPv4/IPv6 • Multicast Listener Discovery (MLD) Snooping • IPv6 ACL • IPv6 Interface • Static IPv6 Routing • IPv6 neighbor discovery (ND) • Path maximum transmission unit (MTU) discovery • Internet Control Message Protocol (ICMP) version 6 • TCPv6/UDPv6 • IPv6 applications: DHCPv6 Client, Ping6, Tracert6, Telnet (v6), IPv6 SNMP, IPv6 SSH, IPv6 SSL, Http/Https, IPv6 TFTP
MIB
• MIB II (RFC1213) • Interface MIB (RFC2233) • Ethernet Interface MIB (RFC1643) • Bridge MIB (RFC1493) • P/Q-Bridge MIB (RFC2674) • RMON MIB (RFC2819) • RMON2 MIB (RFC2021) • Radius Accounting Client MIB (RFC2620) • Radius Authentication Client MIB (RFC2618) • Remote Ping, Traceroute MIB (RFC2925) • Support TP-Link private MIB

MANAGEMENT

Omada app
Yes. Requires an Omada Hardware Controller, Omada Cloud-Based Controller or Omada Software Controller.
Centralized management
• Omada Cloud-Based Controller • Omada Hardware Controller • Omada Software Controller
Cloud access
Yes. Requires an Omada Hardware Controller, Omada Cloud-Based Controller or Omada Software Controller.
Automatic device setup (Zero-Touch Provisioning)
Yes. Requires the use of an Omada Cloud-Based Controller.
Control features
• Web-based GUI • Command Line Interface (CLI) through the console port, telnet • SNMP v1/v2c/v3: Trap/Inform, RMON (1,2,3,9 groups) • SDM Template • DHCP/BOOTP Client • 802.1ab LLDP/LLDP-MED • DHCP Auto Install • Dual Image, Dual Configuration • CPU Monitoring • Cable Diagnostics • Password Recovery • SNTP • System Log

Additional information

Certification
CE, FCC, RoHS
Packaging content
• SX3008F Switch • Power Cord • Quick Installation Guide • Rackmount Kit • Rubber Feet
System requirements
Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux.
Operating conditions
• Operating Temperature: 0–50 ℃ (32–122 ℉); • Storage Temperature: -40–70 ℃ (-40–158 ℉) • Operating Humidity: 10–90% RH non-condensing • Storage Humidity: 5–90% RH non-condensing

Control features

Switch type
Managed
Switch layer
L2/L3
Quality of Service (QoS) support
Yes
Web-based management
Yes
Cloud management
Yes
Traffic classification
Yes
ARP inspection
Yes
Configuration location settings (CLI)
Yes
System event log
Yes
MIB support
RFC2925, RFC2618, RFC2620, RFC2021, RFC2819, RFC2674, RFC1493, RFC1643, RFC2233, RFC1213

Ports & interfaces

Basic switching RJ-45 Ethernet ports type
No
Number of SFP+ module slots
8
Console connection point
RJ-45/micro-USB
Power connector
DC-in jack

Network

Network standard
IEEE 802.1D, IEEE 802.1Q, IEEE 802.1s, IEEE 802.1w, IEEE 802.3ad, IEEE 802.3x
10G support
Yes
Port mirroring
Yes
IP routing
Yes
Flow control support
Yes
Link aggregation
Yes
Broadcast storm control
Yes
Rate limiting
Yes
Spanning Tree Protocol
Yes
Head-of-line (HOL) blocking
Yes
VLAN support
Yes
Virtual LAN features
Private VLAN, protocol-based VLAN, voice VLAN
Number of VLANs
4000

Data transfer

Packet processing capacity
119,04 million packets per second
Number of queues
8
Static routing
Yes
Jumbo frames support
Yes
Jumbo frames
9000

Security

DHCP properties
DHCP relay, DHCP server, DHCP snooping, DHCPv6 client, DHCPv6 snooping
access control list (ACL)
Yes
IGMP snooping
Yes
Supported security algorithms
HTTPS, SSH, SSH-2, SSL/TLS
MAC address filtering
Yes
Static port security
Yes
SSH/SSL support
Yes
Loop protection
Yes
BPDU filtering / guard
Yes
IP-MAC-Port binding
Yes
Authentication
Guest VLAN, MAC-based authentication, Port-based authentication, Web-based authentication
Authentication type
AAA, TACACS+
Row scheduling algorithms
SP, WRR+SP, Weighted Round Robin (WRR)

Multicast features

Multicast support
Yes
Multicast Listener Discovery (MLD) snooping
Y

Protocols

Management protocols
SNMPv1/v2c/v3, SNTP
IPv4 and IPv6 features
IPv6 Telnet, IPv6 ping, IPv6 tracert

Design

Rack mounting
Yes
Product colour
Black
LED indicators
Yes

Power management

Power source
AC
Power supply included
Yes
AC input voltage
220 V
AC input frequency
50/60 Hz
Power consumption (max)
15.46 W

Power over Ethernet (PoE)

Power over Ethernet (PoE)
No

Operational conditions

Operating temperature range (T-T)
0 - 45 °C
Storage temperature (T-T)
-40 - 70 °C
Operating relative humidity range
10 - 90%
Storage relative humidity (H-H)
5 - 90%
Heat dissipation
52,75 BTU/h

Weight and dimensions

Width
440 mm
Depth
180 mm
Height
44 mm

Packaging content

Cables included
AC
Quick start guide
Yes
Manual
Yes
Rack mounting accessories
Yes

Packaging data

Packaging type
Box

Noticed an error in the description or specifications? Please write to us.

TP-LINK Omada switch SX3008F
Copied

Company details

Name
SIA ETEKOS
Reg. No.
44103141108
VAT No.
LV44103141108
Email
info@etekos.lv
Phone
+371 2666 2621

Categories

Report an error

Enter your email only if you want a reply. Privacy policy

Notify me when available

We will send a confirmation link. After that we will tell you once when the product is available. We keep the request for up to 180 days. Privacy policy

Your cart